Review




Structured Review

Bruker Corporation multiplet ppm 3 13c nmr measurement conditions
Multiplet Ppm 3 13c Nmr Measurement Conditions, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 99/100, based on 13255 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multiplet+ppm+3+13c+nmr+measurement+conditions/AVANCE+NEO/us12571099-99-88-100
Average 99 stars, based on 13255 article reviews
multiplet ppm 3 13c nmr measurement conditions - by Bioz Stars, 2026-10
99/100 stars

Images

Related Articles

Analysis:

Article Title: Bis(ethylcyclopentadienyl)tin, precursor for chemical vapor deposition, method of producing tin-containing thin film, and method of producing tin oxide thin film
Article Snippet: .. The obtained sample was analyzed according to the following (1) to (3), whereby the sample was identified as Sn[C5H4 (C2H5)]2. (1) Composition Analysis As a result of ICP atomic emission spectrometry for a liquid obtained by wet decomposition of the sample, the content of Sn was found to be 38.2% (theoretical value: 38.9%). (2) 1H-NMR Measurement conditions (Instrument: AVANCE NEO 500 (500 MHz), Bruker BioSpin GmbH, solvent: THF-d8, method: 1D) CH2CH3, 1.15 (6H, triplet) ppm: CH2CH3, 2.48 (4H, quartet) ppm: C5H4, 5.71 (4H, multiplet) ppm: C5H4, 5.79 (4H, multiplet) ppm (3) 13C-NMR Measurement conditions (Instrument: AVANCE NEO 500 (125 MHz), Bruker BioSpin GmbH, solvent: THF-d8, method: 1D) 133.61, 110.31, 108.37 ppm: C5, 22.53, 16.88 ppm: C2H5 Next, the vapor pressure at from 70 to 130° C. was directly measured using a pressure gauge (Model: 121A, Manufacturer: MKS Instruments, Inc.) to give the following formula. ..

Solvent:

Article Title: Bis(ethylcyclopentadienyl)tin, precursor for chemical vapor deposition, method of producing tin-containing thin film, and method of producing tin oxide thin film
Article Snippet: .. The obtained sample was analyzed according to the following (1) to (3), whereby the sample was identified as Sn[C5H4 (C2H5)]2. (1) Composition Analysis As a result of ICP atomic emission spectrometry for a liquid obtained by wet decomposition of the sample, the content of Sn was found to be 38.2% (theoretical value: 38.9%). (2) 1H-NMR Measurement conditions (Instrument: AVANCE NEO 500 (500 MHz), Bruker BioSpin GmbH, solvent: THF-d8, method: 1D) CH2CH3, 1.15 (6H, triplet) ppm: CH2CH3, 2.48 (4H, quartet) ppm: C5H4, 5.71 (4H, multiplet) ppm: C5H4, 5.79 (4H, multiplet) ppm (3) 13C-NMR Measurement conditions (Instrument: AVANCE NEO 500 (125 MHz), Bruker BioSpin GmbH, solvent: THF-d8, method: 1D) 133.61, 110.31, 108.37 ppm: C5, 22.53, 16.88 ppm: C2H5 Next, the vapor pressure at from 70 to 130° C. was directly measured using a pressure gauge (Model: 121A, Manufacturer: MKS Instruments, Inc.) to give the following formula. ..



Similar Products

99
Bruker Corporation multiplet ppm 3 13c nmr measurement conditions
Multiplet Ppm 3 13c Nmr Measurement Conditions, supplied by Bruker Corporation, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multiplet+ppm+3+13c+nmr+measurement+conditions/AVANCE+NEO/us12571099-99-88-100
Average 99 stars, based on 1 article reviews
multiplet ppm 3 13c nmr measurement conditions - by Bioz Stars, 2026-10
99/100 stars
  Buy from Supplier

Image Search Results